There are various search modes: video type, channel number or time. The system can max
display 128 les in one screen. You can use page up/down button to view if there is more
than one page.
Select the le name and double click mouse (or click enter button), to view le content.
 
There are two playback modes: 4-ch and all-channel. In 4-ch playback mode, you can select
the 1/2/3/4-ch playback according to your requirement. In all-channel mode, the system can
playback in full channels. Please note the 4-ch has no all-channel playback mode.
 
Input time (h/m/s) in the time column and then click playback button, system can operate
time specic playback.
 
During the playback process, click the numeral key, the system will switch to the video
channel corresponding to the same time.
 
When the system is in full-screen playback mode, drag your mouse on the screen to select a
section and then left click mouse to activate the digital zoom. Right click mouse to exit.
 
System supports backup operation during search. Select a √ in front of the le name
(multiple choices), click the backup button (Button 14 in Figure 2-13).
 
Click the calendar icon in Figure 2-13. The system pops up a calendar for your
reference.
The highlighted date means there are record les on that day. You can click the blue date to
view the le list. In the following interface you can see there are video les in 13th June and
14th June. Double click the date to view le list.

 
There are two alarm input types for you to select: normal open (NO) and normal close (NC).
 
Refer to the following table and Figure 1-4 for alarm input and output information

In the rst line, from the left to the right,:
1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14,
15, 16
ALARM 1 to ALARM 16. The alarm
becomes active in low voltage.
In the second line, from the left to the right:
NO1 C1,
NO2 C2,
NO3 C3,
NO4 C4,
NO5 C5 NC5
The rst four are four groups of normal
open activation output (on/off button)
NO5 C5 NC5 is a group of NO/NC
activation output (on/off button)
CTRL 12V
Control power output. You need to close the
device power to cancel the alarm.
+12V
It is external power input. Need the
peripheral equipment to provide +12V
power (below 1A).
Ground cable
485 A/B
485 communication port. They are used
to control devices such as PTZ. Please
parallel connect 120TΩ between A/B cables
if there are too many PTZ decoders.